CS1222 Series

Video & data transmission · CS1222 series

CS1222 Series Video Transmission Module

Wideband wireless transmission with Star and MESH networking options, factory-configured frequency bands, and automatic frequency and power control for UAV and ground-system integration.

Star + MESH23 / 33 dBm designations*600 MHz / 1.4 GHz options1.4–40 MHz bandwidth
CS1222 wireless transmission module with finned enclosure
CS1222 series · original product image
2Network modes
40 MHzHighest listed bandwidth
23 / 33Nominal dBm designations*
2Factory band families
Overview

Flexible Star & MESH Networking

Choose the network topology, frequency option and interfaces that suit the intended civil application.

Wideband wireless access

The CS1222 series supports Star topology for point-to-multipoint communication and MESH topology for adaptable multi-node links. The source lists automatic frequency selection and access-node power adjustment based on network conditions.

The 600 MHz and 1.4 GHz band options are factory configured. Confirm the delivered unit's exact band and settings before use.

CS1222 module with antennas at an outdoor site
Example outdoor installation; conditions vary.

Key capabilities

01

Star & MESH

Point-to-multipoint and self-organizing topology options.

02

Factory-set bands

600 MHz and 1.4 GHz band families listed in the supplied source.

03

Model-dependent power

CS1222-23 and CS1222-33 designations; confirm the actual output ceiling.

04

Flexible bandwidth

1.4 / 3 / 5 / 10 / 20 / 40 MHz source-listed options.

05

Frequency control

Can scan preset frequencies after link synchronization is lost.

06

Power adjustment

Access-node output may adapt to signal quality within verified limits.

Diagram of Ethernet devices connected by wireless modules
Illustrative wireless link architecture.
Specifications

Typical Rated Values

Two populated model rows from the supplied source; blank rows removed.

Model Supply voltage Max. system power Source-listed TX rating
CS1222-23 12–27 V 5 ± 1 W 23 ± 3 dBm*
CS1222-33 16–27 V 27 ± 5 W 33 ± 3 dBm*
−20 to +55 °COperating temperature
−40 to +85 °CStorage temperature
5–95%Humidity, non-condensing
Installation & safety
  • Connect TX/RX antennas as instructed; operating without antennas may damage the device.
  • Provide adequate heat dissipation during continuous use.
  • Received signal strength at any receiving port must not exceed +10 dBm.
  • The source recommends more than 0.2 m between antennas on the same module and more than 1 m between separate modules.
Configuration

Frequency, Bandwidth & Control

Choose a factory configuration appropriate for the intended region and applicable spectrum rules.

Frequency band families

  • 600 MHz band: 566–678 MHz.
  • 1.4 GHz band: 1420–1530 MHz.
  • Exact center frequency depends on the ordered model.
  • Factory customization may be available; users cannot freely change bands.

Bandwidth options

  • 1.4 / 3 / 5 MHz.
  • 10 / 20 / 40 MHz.
  • Available settings and data rate depend on the specific unit.

Automatic frequency control

On startup the module attempts its stored frequency. If the network is unavailable, it can scan preset frequencies and rejoin.

Automatic power control

The center node uses its configured rated output. Access-node output can adapt to signal quality but must remain within a verified limit.

Connectivity

Interfaces & Ports

The supply range depends on model; the connector artwork's 24 V label is a reference marking, not a universal limit.

CS1222 connector layout: LAN, DEBUG, DDT, USB and power
Connector positions; refer to the model-specific voltage table above.

LAN · Ethernet

PH2.0-4 · RX− / RX+ / TX− / TX+ · 10/100 Mbit/s.

DEBUG serial

PH2.0-3 · R2 / GND / T2 · default RS232 level.

DDT data serial

PH2.0-3 · R1 / GND / T1 · default RS232 level.

USB 2.0

Micro USB connector; USB 2.0 standard.

Power input

XT30PW-M · GND / VCC. See the model-specific voltage range.

RF ports × 2

SMA-K primary and secondary antenna ports.

Indicators

LED Indicator Guide

Master / Slave

Solid on in Master mode; blinking in Slave mode.

LED 1 · Link

After link establishment, green indicates center node and red indicates access node.

LED 2 · Ethernet

Rapid blinking during power-up self-test; blinks with traffic.

LED 3 · System

Orange indicates error; green indicates normal operation.

Mechanical

Dimensions & Weight

Unspecified CS1222-23 figures are not estimated.

Model Weight Dimensions
CS1222-23 Not specified Not specified
CS1222-33 235 g See model drawing
CS1222-33 multi-view dimensional drawing
CS1222-33 original model drawing.
Included

Accessory List

Source-listed accessories; confirm final package contents.

Ethernet cables

PH2.0-to-RJ45 · 1.5 m × 2 pcs.

Serial cables

PH2.0 · 0.2 m × 2 pcs.

Power cable

XT30-to-DC · 0.3 m × 1 pc.

Optional USB cable

Micro USB · 1 m × 1 pc, if ordered.

Ordering guide

Model Naming & Examples

Only non-empty, internally consistent source entries are retained.

CS1222-33-1475

CS1222 — module platform
33 — nominal power designation in dBm*
1475 — center frequency in MHz

Source-listed ordering examples

Network mode Power designation* Frequency range Product model
Star 33 dBm 634–674 MHz CS1222-33-654
Star 33 dBm 1420–1530 MHz CS1222-33-1475
MESH 33 dBm 1420–1530 MHz CS1222-33-1475
Use cases

Typical Applications

Examples for permitted civil deployments with a suitable configuration.

Point-to-multipoint links

Connect a central station with multiple field nodes.

Utility & hydrology inspection

Transfer video and data for infrastructure and environmental monitoring.

Fire & emergency response

Establish temporary on-site connectivity where existing infrastructure is unavailable.

Select a verified CS1222 configuration

Share your band, topology, interface and deployment needs with CroSkylink, and request confirmation of the required output and distance limits.

Contact CroSkylink